high resolution ICP-MS

High-Resolution ICP-MS

Thermo Element XR magnetic-sector ICP-MS. Multi-element analysis from mg/L down to sub-pg/L, with high mass resolution that separates interferences, and isotope ratio measurements. Laser ablation can be coupled for solid samples.

Rate: $70 / hour (academic). All rates

Hazardous materials: If your sample is radioactive or highly toxic, you MUST disclose this to MATFab staff before booking. Special safety protocols apply.

Specialist: Linhan Li, Core Facility Research Specialist

Email Li · Book on BookitLab

ICP-MS

Agilent 7800 Quadrupole ICP-MS

Agilent 7800 quadrupole ICP-MS. Multi-element analysis of dissolved samples from 6Li to 238U, down to parts per trillion. Samples must be clear, dilute solutions; solids are digested first. Also supports single-particle ICP-MS (SP-ICP-MS) for nanoparticles.

Rate: $50 / hour (academic). All rates

Hazardous materials: Radioactive or highly toxic samples require advance notice and special handling approval.

Specialist: Linhan Li, Core Facility Research Specialist

Email Li · Book on BookitLab

Compare the instruments

PropertyHigh-Resolution ICP-MSAgilent 7800 Quadrupole ICP-MS
SummaryThermo Element XR magnetic-sector ICP-MS. Multi-element analysis from mg/L down to sub-pg/L, with high mass resolution that separates interferences, and isotope ratio measurements. Laser ablation can be coupled for solid samples.Agilent 7800 quadrupole ICP-MS. Multi-element analysis of dissolved samples from 6Li to 238U, down to parts per trillion. Samples must be clear, dilute solutions; solids are digested first. Also supports single-particle ICP-MS (SP-ICP-MS) for nanoparticles.
Choose it whenChoose the HR-ICP-MS for the lowest concentrations, for elements with strong spectral interferences, or for precise isotope ratios.Choose the ICP-MS for routine trace and ultra-trace analysis of many dilute solutions: lower detection limits than the ICP-OES, and a lower rate than the HR-ICP-MS.
StrengthsHigh mass resolution separates interferences that a quadrupole cannot
Concentration range from mg/L down to sub-pg/L (about 9 orders of magnitude)
Isotope ratios better than ±0.1% for Pb, Sr and Li
Autosampler with online dilution; as little as 0.5 mL of sample per run
Detects parts per trillion or better
Collision/reaction cell removes argon-based interferences (for example on As and Se)
Autosampler holds more than 200 samples
Single-particle ICP-MS for nanoparticles
LimitationsHigher hourly rate than the quadrupole ICP-MS
Samples must be dissolved, unless laser ablation is used
Dissolved solids above 0.1 wt.% cannot be analyzed; samples must be diluted
Lower mass resolution than the HR-ICP-MS for difficult interferences
Solids must be digested first
Rate$70 / hour (academic)$50 / hour (academic)
ApplicationsGeochemistry
Environmental analysis
Trace metal detection
Geochronology (isotope ratio analysis)
Ultra-trace elemental mapping (via LA coupling)
Materials science
Biological samples
Pharmaceutical analysis
Food science
Environmental testing
Nanoparticle characterization (SP-ICP-MS)
Sample typesDissolved solutions
Digested solids
Aqueous samples
Dissolved solutions
Digested samples
Liquids
Nanoparticle suspensions
Sample prepSamples must be fully dissolved in 2-5% HNO3 or HCl
No HF unless specifically discussed with staff beforehand
Total dissolved solids (TDS) should be < 0.2%
Volume: minimum 3 mL per sample
Include blank and calibration standards
Samples with high matrix (e.g., seawater) may need dilution
Samples must be dissolved in aqueous solution (2-5% HNO3 recommended)
No HF without prior approval from staff
TDS must be below 0.1% (dilute if needed)
Minimum volume: 3 mL per sample
Provide estimated concentration range
Include at least one blank and reference standard
For SP-ICP-MS: provide information on expected particle size range and concentration
ConstraintsHazardous: If your sample is radioactive or highly toxic, you MUST disclose this to MATFab staff before booking. Special safety protocols apply.Hazardous: Radioactive or highly toxic samples require advance notice and special handling approval.
Note MATFab runs two ICP-MS instruments: this Agilent 7800 quadrupole for routine trace work, and the Thermo Fisher HR-ICP-MS for ultra-trace and isotope-ratio work. Contact staff if you are unsure which fits your project.

Still not sure which instrument to use?