Elemental Analyzer

Combustion Elemental Analyzer (CHN)

Measures carbon, hydrogen and nitrogen content of solid samples by combustion; the system can also be configured to measure sulfur. Uses less than 3 mg of material per sample.

Rate: $25 setup + $5 / sample. All rates

Specialist: Michael Sinnwell, Core Facility Research Specialist

Email Sinnwell · Book on BookitLab

LIBS (ESLumen)

Laser-Induced Breakdown Spectroscopy. A high-energy laser pulse creates a micro-plasma on the sample surface, and the emitted light is analyzed by a spectrometer. Excellent for light elements (H, Li, B, C, N, O, F, Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, etc.) and halogens (F, Cl, Br, I) that conventional ICP-MS struggles to measure. Very fast (seconds per spot). Can map element distributions.

Rate: $20 / hour (academic). All rates

Specialist: Linhan Li, Core Facility Research Specialist

Email Li · Book on BookitLab

Compare the instruments

PropertyCombustion Elemental Analyzer (CHN)LIBS (ESLumen)
SummaryMeasures carbon, hydrogen and nitrogen content of solid samples by combustion; the system can also be configured to measure sulfur. Uses less than 3 mg of material per sample.Laser-Induced Breakdown Spectroscopy. A high-energy laser pulse creates a micro-plasma on the sample surface, and the emitted light is analyzed by a spectrometer. Excellent for light elements (H, Li, B, C, N, O, F, Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, etc.) and halogens (F, Cl, Br, I) that conventional ICP-MS struggles to measure. Very fast (seconds per spot). Can map element distributions.
Choose it whenChoose the CHN analyzer for the carbon, hydrogen and nitrogen content of a sample (and sulfur, when configured), for example to confirm the purity of a new compound.Choose LIBS for halogens (F, Cl, Br, I) and light elements in solids, or for fast screening and element maps without digestion. If you need both C, H, N and halogens, book both instruments.
StrengthsAccuracy within 0.20% by mass
Uses less than 3 mg per sample
Detects light elements and halogens that ICP-MS measures poorly
No digestion; works directly on solids
Seconds per spot; can map element distributions
LimitationsDestructive
Measures only C, H and N (and S when configured): no halogens or metals
Less precise than ICP-MS or combustion analysis; quantitative results need matched standards
Removes a tiny amount of material at each spot
Rate$25 setup + $5 / sample$20 / hour (academic)
ApplicationsOrganic chemistry
Polymers
Soil & sediment
Plant tissue
Coal & coke
Catalysts
Geology & mineralogy
Light element analysis (H, Li, B, C, N, O, F)
Halogen detection (F, Cl, Br, I): ideal for this
Metallurgy & alloys
Forensics & provenance
Environmental screening
Biological materials
Art & archaeology
Sample typesDry powders
Solid organic materials
Liquids (in sealed capsules)
Solids (any material)
Powders (pressed pellets)
Rough surfaces
Sample prepSample must be completely dry: no moisture
Weigh less than 3 mg into tin or silver capsules (provided by facility)
Homogeneous samples preferred (grind if heterogeneous)
Avoid samples containing halogens in high concentrations without consultation
Liquids must be sealed in gelatin capsules: discuss with staff first
Minimal sample preparation: works on almost any solid surface
Sample must be flat enough for the laser to focus
Powder samples can be pressed into pellets
Rough or uneven surfaces are generally acceptable
Discuss expected concentrations and target elements with staff
Sample is consumed only at the laser spot (~10 to 100 μm crater)